As we know, the main energy of solar street light is solar energy, so it is the best in street light, because it is sunlight in the daytime on the solar cell, the light energy into electrical energy stored in the battery, and then the battery in the evening for the LED street light (LED) to provide power. Below, solar street lamp technicians will explain the main protection mode of solar street lamp for you:

Mode 1. Direct charge protection point voltage

Direct charge is also called emergency charge, which belongs to fast charging. It is generally used when the battery voltage is low with large current and relatively high voltage to charge the battery, but there is a control point, also called the protection point. Direct charge protection point voltage is generally "overcharge protection point" voltage, charging battery terminal voltage cannot be higher than this protection point, otherwise it will cause overcharge, damage to the battery.

Mode 2. Voltage of equalized charge control point:

After the direct charge is complete, the battery is generally left for a period of time by the charge and discharge controller to let its voltage drop naturally. When the voltage drops to the "Recovery voltage" value, the battery enters the equalized charge state. Equalized charging, or "balanced charging." The equalized charging time should not be too long, generally a few minutes to ten minutes, too long time is harmful. For small systems equipped with one or two batteries, equalization is of little significance. So. Solar street lamp controller generally does not set uniform charge, only two stages.

Mode 3. Voltage of floating charge control point:

Generally, after all charges are completed, the battery is also placed for a period of time to make its terminal voltage drop naturally. When it falls to the maintenance voltage "point, it enters the floating charge state. Similar to small current charging, battery voltage is low on the charge of a point, a low charge on a point, a stream to avoid the battery temperature continues to rise, which is very good for the battery.

Mode 4. Overdischarge protection termination voltage:

The battery discharge should not be lower than the national standard. Although battery manufacturers also have their own protection parameters, but ultimately close to the NATIONAL standard.

For the sake of safety, the general 12V battery overdischarge protection point voltage artificially plus 0.3V as temperature compensation or control circuit zero drift correction, so 12V battery overdischarge protection point voltage is: 11.10V, then the 24V system overdischarge protection point voltage is 22.20V.


分享 
Свържете се с нас сега
Shenzhen Taiwoo Battery Co., Ltd.
2F, Building A, Junxinglong Industrial Park, Zhoushi Road, Shiyan Street, Baoan District, Shenzhen City, Guangzhou Province, P, R.China
Можеш да ни се довериш.
Ние сме професионален производител в Китай, ние продължаваме да иновационираме, така че нашите клиенти да могат да имат по-добри продукти и услуги.
© Shenzhen Taiwoo Battery Co., Ltd.    СВЪРЗАНИ СТАТИИ     Условия на услугата        Клауза за поверителност     
Въведете вашите данни за запитване и ние ще ви отговорим в рамките на 24 часа.
Името не може да бъде празно
Пощенската кутия не може да бъде празна
Компанията не може да е празна.
Мобилният телефон не може да бъде празен
Страната не може да бъде празна
Информацията не може да бъде празна
празен